Compatibility Matrix

Appearance
Clear & Bright
Clear & Bright
Clear & Bright
Clear & Bright
Clear & Bright
Clear & Bright
Clear & Bright
Flash Point
None
None
None
None
None
None
None
Boiling Point
°C (°F)
45.5 (113.9)
39 (102)
38 (100)
42 (108)
42 (108)
56 (133)
54 (129)
KB Value
94
63
62
74
81
13
13
Specific Gravity
g/mL @ 25°C
1.272
1.362
1.359
1.32
1.318
1.47
1.426
Viscosity
cP @ 20°C
0.41
0.41
0.41
0.41
0.41
0.65
0.63
Heat Capacity
cal/g @ 20°C
0.27
0.270
0.270
0.270
0.270
0.306
0.306
Vapor Pressure
mmHg @ 20°C
292
368
368
368
343
233
233
Lower Limit Vapor Flammability in Air
5.70%
6.70%
6.70%
6.70%
6.70%
Upper Limit Vapor Flammability in Air
19%
19%
19%
19%
19%
VOC Content
g/L
1115
587
547
771
770
Exempt
71.3
ABS
N
n
N
N
N
R
R
Cast Acrylic
N
N
N
N
N
N
N
Cast Nylon 6
R
R
R
R
R
R
r
Cellulose-Acetate​
R
R
R
R
R
R
r
CPVC
N
N
N
N
N
N
N
Delrin
R
R
R
R
R
R
r
Extruded Acrylic
N
N
N
N
N
N
N
Extruded Nylon 6/6
R
R
R
R
R
R
r
FEP
R
R
R
R
R
R
r
HDPE
M
M
M
M
M
R
r
LDPE
N
M
M
M
M
M
r
Noryl PPO
N
N
N
N
N
M
M
PEEK
R
R
R
R
R
R
r
PETG
N
N
N
N
N
M
M
PFA
M
M
M
M
M
R
r
Polycarbonate
N
N
N
N
N
N
N
Polyester
R
R
R
R
R
R
r
Polyimide
N
N
N
N
N
M
M
Polypropylene
N
N
N
N
N
M
M
Polystyrene
N
N
N
N
N
R
R
Polysulfone
M
M
M
M
M
M
M
PPS
R
R
R
R
R
R
r
PVC Clear
N
N
N
N
N
N
N
Rexolite
N
N
N
N
N
M
R
Torlon PAI
R
R
R
R
R
R
r
UHMW
M
M
M
M
M
M
M
Ultem
M
M
M
M
M
M
M
R - REcommended
M - Marginal
N - Not Recommended

Compatibility is based on full immersion tests of three different lengths: 2hr, 4hr, and 24 hr. 

The worst of any of these tests is the prevailing recommendation of compatibility. 

A test coupon sourced from McMaster Carr is cut into a 1” x 1” square and weighed and measured. The prevailing method we use for compatibility is weight. The measurements can be used if there is a noticeable physical change. IF there is noticeable cracking or physical breakdown that warrants a non-compatibility, but the weight passed, the compatibility will be based off of the physical. 

A new coupon is used for each immersion. The coupons are immersed in a sealed container for the prescribed time and then taken out. They are dried for 2 minutes, allowing for surface evaporation, and then weighed. 

R < 2wt% change 

M = 2-8 wt% change 

N > 8 wt% change